Overview

CHARACTERISTICS

Voltage Rating Uo/U

450/750V

Temperature Rating

-15°C to +70°C

Minimum Bending Radius

Up to 10mm²: 5 x overall diameter

10mm² to 25mm²: 8 x overall diameter

Above 25mm²: 10 x overall diameter

CONSTRUCTION


STANDARDS

EN 50525-2-31

VDE 0298 Part 4

EN 50565-1/ VDE 0298-565-1

Flame Retardant according to IEC/EN 60332-1-2




Construction

Conductor

Class 2 stranded copper conductor

Insulation

PVC (Polyvinyl Chloride)

Insulation Colour

Red Black Blue Yellow White Green/Yellow

Grey Brown

Note

1.5mm² to 50mm² also available as H07V-U Class 1 solid

copper conductor

Parameter
H07V-U
H07V-R
H07V-K
Solid standard 450/750V IEC 60227 (H07V-U) CU/PVC
NO./mm2φ Of Conductor(mm)Insulation thickness (mm)Diameter of cable(mm)CU weight
(kg/km)
Weight
of cable
(kg/km)
DC Resistance
(Ω/km)
Carrying capacity(A)
1*1.51.38 0.7 2.78 13.54 20.27 12.100 21 
1*2.51.78 0.8 3.38 22.56 32.12 7.410 29 
1*42.26 0.8 3.86 36.09 47.40 4.610 38 
1*62.76 0.8 4.36 54.14 67.32 3.080 49 
1*103.57 1.0 5.57 90.23 111.36 1.830 68 
1*164.51 1.0 6.51 144.37 169.87 1.150 91 
1*255.64 1.2 8.04 225.58 263.55 0.727 120 
1*356.68 1.2 9.08 315.82 359.51 0.524 150 
1*507.98 1.4 10.78 451.17 511.88 0.387 180 
Stranded conductor 450/750V standard IEC 60227 (H07V-R) CU/PVC
NO./mm2φ Of Conductor(mm)Insulation thickness (mm)Diameter of cable(mm)CU weight
(kg/km)
Weight
of cable
(kg/km)
DC Resistance
(Ω/km)
Carrying capacity(A)
1*1.50.7 2.97 13.54 20.87 12.100 21 
1*2.50.8 3.62 22.56 33.00 7.410 29 
1*40.8 4.16 36.09 48.52 4.610 38 
1*60.8 4.73 54.14 68.69 3.080 49 
1*101.0 6.05 90.23 113.56 1.830 68 
1*161.0 7.12 144.37 172.66 1.150 91 
1*251.2 8.80 225.58 267.74 0.727 120 
1*351.2 9.97 315.82 364.47 0.524 150 
1*5019 1.4 11.95 451.17 519.47 0.387 180 
1*7019 1.4 13.63 631.63 710.80 0.268 230 
1*9519 1.6 15.82 857.22 962.38 0.193 290 
1*12019 1.6 17.38 1082.80 1199.53 0.153 335 
1*15037 1.8 19.50 1353.50 1500.84 0.124 390 
1*18537 2.0 21.66 1669.32 1851.14 0.099 450 
1*24061 2.2 24.54 2165.60 2392.88 0.075 545 
Flexible conductor 450/750V standard IEC 60227 (H07V-K) CU/PVC
NO./mm2φ Of Conductor(mm)Insulation thickness (mm)Diameter of cable(mm)CU weight
(kg/km)
Weight
of cable
(kg/km)
DC Resistance
(Ω/km)
Carrying capacity(A)
1*1.50.25 0.7 2.98 13.54 20.91 13.300 21 
1*2.50.25 0.8 3.85 22.56 33.84 7.980 29 
1*40.30 0.8 4.57 36.09 50.04 4.950 38 
1*60.30 0.8 5.32 54.14 70.86 3.300 49 
1*100.40 1.0 6.95 90.23 117.74 1.910 68 
1*160.40 1.0 7.88 144.37 176.18 1.210 91 
1*250.40 1.2 9.75 225.58 273.02 0.780 120 
1*350.40 1.2 10.74 315.82 368.75 0.554 150 
1*500.40 1.4 12.96 451.17 526.00 0.386 180 
1*700.50 1.4 15.10 631.63 720.32 0.272 230 
1*950.50 1.6 18.10 857.22 979.28 0.206 290 
1*1200.50 1.6 19.01 1082.80 1211.60 0.161 335 
1*1500.50 1.8 20.80 1353.50 1511.63 0.129 390 
1*1850.50 2.0 23.95 1669.32 1872.30 0.106 450 
1*2400.50 2.2 26.83 2165.60 2416.14 0.080 545