Overview

Characteristics
We manufacture 3-core armoured array cables, with copper or aluminum conductors and cross-sections up to 1000 mm².

For the shielding, copper wires are used,or coating with layers of copper, aluminum or lead.

The continuous increase of offshore wind farm sizes and wind turbine output power, has given rise to a clear trend towards higher voltage array cabling.

We currently offer 45 kV inter array cables and consider the development of higher voltages.:

1. It doubles the power that can be transported over one cable, thus reducing the total length of cable required.

2. Fewer overall cables are required, thus reducing the amount of accessories and equipment required.

3.Single-mode or multi-mode optical fiber (G 652D & G 655): 1~144 cores


Standards

ISO/IEC 63026

IEC 60228

IEC 60502

IEC 60840

IEC 62067

Construction

1.Conductor:

Al or Cu round stranded

Semiconducting tape

Conductor non-metallic extruded screencompound

2.Insulation:

XLPE water-tree retardant

Core non-metallic extruded screen

Semiconducting waterblocking tape(s)

3.Radial watertightness:

lead sheath

4.Sheath:

HDPE and extruded semiconducting compound

Extruded profile fillers

Binding tape(s) with overlap

Polypropylene yarns, One layerstripe

Armouring: helically applied bitumen compound coated

5.Single-mode or multi-mode optical fiber (G 652D & G 655):

1~144 cores

galvanized round steel wires

Polypropylene yarns, two layers

Parameter
8.7/15 kV Three-core cables with lead sheath
12/20 kV Three-core cables with lead sheath
18/30 kV Three-core cables with lead sheath
26/35 kV Three-core cables with lead sheath
8.7/15 kV Three-core cables with lead sheath(optical fiber (G 652D & G 655): 1~144 cores)
NO./mm2Conductor NO.Insulation thickness (mm)Lead sheath (mm)PE sheath thickness (mm)Armour of wire(mm)Diameter of cable(mm)CU weight
(kg/km)
Weight
of cable
(kg/km)
DC Resistance
(Ω/km)
3*9519 4.5 1.4 2.1 92.03 2571.65 17610.10 0.1930 
3*12037 4.5 1.5 2.1 95.42 3248.41 19204.26 0.1530 
3*15037 4.5 1.5 2.2 99.87 4060.51 20991.04 0.1240 
3*18537 4.5 1.6 2.2 103.57 5007.96 22978.19 0.0991 
3*24061 4.5 1.6 2.3 108.79 6496.81 25967.66 0.0754 
3*30061 4.5 1.7 2.4 113.79 8121.02 29065.90 0.0601 
3*40061 4.5 1.8 2.5 121.12 10828.02 33997.15 0.0470 
3*50061 4.5 1.9 2.7 127.57 13535.03 38727.04 0.0366 
3*63061 4.5 2.0 2.8 135.06 17054.13 44667.64 0.0283 
3*80091 4.5 2.1 2.9 143.83 21656.04 52203.00 0.0221 
3*100091 4.5 2.2 3.1 152.96 27070.05 60792.32 0.0176 
12/20 kV Three-core cables with lead sheath(optical fiber (G 652D & G 655): 1~144 cores)
NO./mm2Conductor NO.Insulation thickness (mm)Lead sheath (mm)PE sheath thickness (mm)Armour of wire(mm)Diameter of cable(mm)CU weight
(kg/km)
Weight
of cable
(kg/km)
DC Resistance
(Ω/km)
3*9519 5.5 1.5 2.1 103.89 2571.65 18974.70 0.1930 
3*12037 5.5 1.5 2.2 107.68 3248.41 20604.14 0.1530 
3*15037 5.5 1.6 2.3 111.63 4060.51 22427.74 0.1240 
3*18537 5.5 1.6 2.3 115.77 5007.96 24453.44 0.0991 
3*24061 5.5 1.7 2.4 121.62 6496.81 27497.33 0.0754 
3*30061 5.5 1.8 2.5 127.22 8121.02 30647.71 0.0601 
3*40061 5.5 1.8 2.6 135.43 10828.02 35655.34 0.0470 
3*50061 5.5 1.9 2.7 142.66 13535.03 40452.54 0.0366 
3*63061 5.5 2.0 2.9 151.05 17054.13 46471.24 0.0283 
3*80091 5.5 2.1 3.0 160.86 21656.04 54097.94 0.0221 
3*100091 5.5 2.3 3.2 171.09 27070.05 62782.51 0.0176 
18/30 kV Three-core cables with lead sheath(optical fiber (G 652D & G 655): 1~144 cores)
NO./mm2Conductor NO.Insulation thickness (mm)Lead sheath (mm)PE sheath thickness (mm)Armour of wire(mm)Diameter of cable(mm)CU weight
(kg/km)
Weight
of cable
(kg/km)
DC Resistance
(Ω/km)
3*9519 8.0 1.6 2.3 116.83 2571.65 17903.97 0.1930 
3*12037 8.0 1.7 2.4 120.62 3248.41 19178.14 0.1530 
3*15037 8.0 1.7 2.5 124.58 4060.51 21309.01 0.1240 
3*18537 8.0 1.8 2.5 128.72 5007.96 22913.01 0.0991 
3*24061 8.0 1.8 2.6 134.56 6496.81 25331.49 0.0754 
3*30061 8.0 1.9 2.7 140.16 8121.02 28480.07 0.0601 
3*40061 8.0 2.0 2.8 148.37 10828.02 32502.56 0.0470 
3*50061 8.0 2.1 2.9 155.60 13535.03 36374.14 0.0366 
3*63061 8.0 2.2 3.1 163.99 17054.13 41251.08 0.0283 
3*80091 8.0 2.3 3.2 173.80 21656.04 47450.06 0.0221 
3*100091 8.0 2.4 3.4 184.04 27070.05 54539.78 0.0176 
26/35 kV Three-core cables with lead sheath(optical fiber (G 652D & G 655): 1~144 cores)
NO./mm2Conductor NO.Insulation thickness (mm)Lead sheath (mm)PE sheath thickness (mm)Armour of wire(mm)Diameter of cable(mm)CU weight
(kg/km)
Weight
of cable
(kg/km)
DC Resistance
(Ω/km)
3*9519 10.3 1.8 2.5 128.74 2571.65 22597.03 0.1930 
3*12037 10.3 1.8 2.6 132.53 3248.41 24314.68 0.1530 
3*15037 10.3 1.9 2.6 136.48 4060.51 26230.32 0.1240 
3*18537 10.3 1.9 2.7 140.62 5007.96 28352.40 0.0991 
3*24061 10.3 2.0 2.8 146.47 6496.81 31532.34 0.0754 
3*30061 10.3 2.0 2.9 152.07 8121.02 34813.05 0.0601 
3*40061 10.3 2.1 3.0 160.28 10828.02 40011.68 0.0470 
3*50061 10.3 2.2 3.1 167.51 13535.03 44977.14 0.0366 
3*63061 10.3 2.3 3.2 177.90 17054.13 51191.08 0.0283 
3*80091 10.3 2.4 3.4 187.71 21656.04 59046.13 0.0221 
3*100091 10.3 2.5 3.5 197.94 27070.05 67968.83 0.0176